  • 7” TFT LCD screen displays the Ventilation parameters, Alarming information and Waveform.
  • Integration breathing circuit design, ensure easy operating and keep tidy.
  • Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects.
  • Multiple Ventilation mode, suitable for different clinical need.
  • Electronic control mixed gas blender, high precision adjustment.
  • Built-in concentration monitoring system, real-time monitoring of airway pressure.
  • Application

    The Veterinary Anesthesia machine makes a good performance in animal clinics. From high to low acuity, simple to complex cases, small to big animals, YBO Medical Anesthesia Systems offer you the choices you need in ventilation, monitoring and technique. what’s more, our expertise in anesthesia delivery and ventilation is based on rich 23-year history of developing anesthesia solutions that meet your needs. Good performance based on High Security, High Accuracy, High Stability and accurate monitoring.

    Safety
  • Three level alarming system, visual and sound alarm information.
  • With lots of alarming, reminding and protection functions.
  • Advanced power management control technology.
  • With built-in backup power source, when outside power source goes off, back-up power source starts to work.
  • Specification
    Ventilation modes DM6B
    Ventilator parameter ranges  
    Tidal volume(Vt) 0, 20 mL ~ 1500 mL
    Frequence(Freq) 1bpm ~ 100 bpm
    I/E 2:1~1:6
    Pressure Limit 20 cmH2O ~ 100 cmH2O
      Monitored Parameters
    Frequence(Freq) 0 /min ~ 100 /min
    Tidal volume(Vt) 0 mL ~ 2000 mL
    MV 0 L/min ~ 100 L/min
      Graphical display: 
    P-T(pressure – time)  
    F-T(flow – time)  
      Size
    1. Wooden case packing size:810*W 760*H 520mm , GW:53KG ; NW:30KG 2. Wooden case packing size:650*W 690*H 520mm , GW:40KG ; NW:20KG
      Alarm and protection  
    The AC power failure alarm Power failure or no connection
    Internal battery backup low voltage alarm <11.3±0.3V
    No tidal volume 5Ml within 6s
    High oxygen concentration alarm Low oxygen concentration alarm 19%-100% 18%-99%
    High Airway  pressure alarm Low Airway  pressure alarm High Minute Volume alarm Low Minute Volume alarm Continuous Pressure alarm 20cmH2O-100cmH2O 0cmH2O-20cmH2O Adult(5L/min-20L/min) Paed(1L/min-15L/min 0-10L/min) (PEEP+1.5kPa) over 16s
    Suffocation warning 5s-60s no spontaneous ventilation
    The maximum limited pressure   <12.5 kPa
    Fan error Oxygen deficit Show on screen Show on screen
      Working conditions
    Gas source O2
    Pressure 280kPa-600kPa
    Voltage 100-240V
    Power frequency 50/60Hz
    Input power 60VA