ultrassay™ Nano-500 micro-spectrophotometer is an advanced model of micro UV VIS spectrophotometer based on Nano-300, with full range of wavelength (200-800 nm). It is with an added new function of bacterium cell concentration measurement (OD600) in a cuvette. The Nano-500 only requires 0.5-2 μl sample to measure nucleic acids, proteins as quickly as Nano-300. Nano-500 come with a 7 inch touch screen and integrated Android operating system, with no computer required. It is an ideal equipment for a biology laboratory to make life science research more efficient.
Introduction
•Android system operation, 7 inch touch screen no computer, APP software, simple interface, easy to use
•To detect the concentration of bacteria and microorganism are more convenient with the OD600 function
•With a 2048-element linear CCD array detector, the detection and display can be completed in 5 seconds.
•The patented lifring motor structure makes the liquid column stretch more gentle, preventing the liquid column from breaking due the structural problems.
•Long-life plsed xenon light source.
•The result can be printed with built-in printer, the data can output via USB for data analysis and storage.
Application Range
260nm: dsDNA, ssDNA, RNA 595nm: Bradford
280nm: A280, BSA, IgG, Lysozyme 600nm: Bacterial concentration
562nm: BCA 650nm: Lowry
Application of different florscence channel
Channel | Excitation Filters | Normal Kits | Application |
UV channel | 365 20nm | Hoechst 33258, 4-MU, EnZCheK Caspase | Nuclear acid quantification, Plant GUS reporter gene detection, Poptosis detection |
Blue channel | 460 20nm | PicoGreen, oligreen, RiboGeen, GFP, Protein, Fluorescein, Quant-iT | dsDNA, ssDNA, RNA quantificatioon, GFP gene detection, Fluorescen detection, Protein detection |
Green channel | 525 20nm | Rhodamine, Cy3, RFP Vybrant Cytotoxicity | Rhodamine detectioon, Cy-3 fluorescence labeling detection, RFP gene detection, Cell activity position detectioon |
Red channel | 625 20nm | Cy5, Quant-iT RNA | Cy-5 fluorescence labeling detection, RNA quantification |
Technical Specification
Model | Nano-500 Micro-spectrophotometer |
Wavelength Range | 200nm – 800nm |
Mini. Sample size | 0.5-2.0 μl |
Path length | 0.05mm, 0.2 mm, 1.0mm |
Light source | Xenon flash lamp |
Detector type | 2048-linear CCD array |
Wavelength accuracy | 1 nm |
Spectral resolution | ≤3 nm (FWHM at Hg546 nm) |
Absorbance precision | 0.003Abs |
Absorbance accuracy | 1%(7.332Abs at 260 nm) |
Absorbance range | 0.04 – 300 A |
Detects nucleic acid up to | 2~15000 ng/μl (dsDNA) |
Measurement time | <6 S |
Data output | USB |
Sample pedestal material | Aluminum alloy and Quartz fiber |
Operating voltage | DC 24 V 2 A |
Operating power | 25 W |
Standby power | 5 W |
Dimension (W×D×H) mm | 208×320×186 |
Weight | 3.6 kg |
Software compatibility | Android system |
OD600nm measurement | |
Light source | LED |
Wavelength range | 600±8 nm |
Abosorbance range | 0-4 A |
Fluorescent detection | |
Sensitivity | dsDNA:0.5 pg/μl |
Linear dynamic range | R²≥0.995 |
Repeatability | ≤1.5 % |
Related suggestion